FIRESAFE || K90
FIRESAFE || K90

‎FIRESAFE® ΙΙ K90 - Accessory components

 

Electrical control unit FSM 10 for monitored shut-off

Firesafe II K90 Bedieneinheit FSM10

The electrical control unit FSM 10 serves the purpose of monitored shut-off of the FIRESAFE II K90.

Consists of:

  • housing
  • 1 sensing device
  • 1 LED red, display of thermal tripping

Pushbutton type DKT 2.2_A

Firesafe II K90 Drucktaster DKT 22 A

To be connected to electrical control unit FSM 10 or control unit FSM 1. The pushbutton type 2 DKT 2.2_A serves to externally trigger the holding mechanism of the FIRESAFE II KI90.

Consists of:

  • aluminium die-cast-housing LxWxH: 125x125x35 mm
  • 2 cable entries screw cap M20x1,5
  • 1 button with locking mechanism for manual release
  • labelling: Close FIRESAFE II K90

Pushbutton type DKT 2.3_R

Firesafe II K90 Drucktaster DKT 23 R

To be connected to control unit FSM 1. The pushbutton type 2 DKT 2.3_R serves to comfortably open the FIRESAFE II K90 via electrical rising-device (external reserve)

Consists of:

  • aluminium die-cast-housing LxWxH: 125x125x35 mm
  • 2 cable entries, screw cap M20x1,5
  • 1 button without locking mechanism
  • labelling: Open FIRESAFE II K90

Electrical rising-device FEAH 1.0 for comfort opening of the FIRESAFE II K90

Firesafe II K90 elektrische Auffahrhilfe FEAH10 
Firesafe II K90 Spiegelung FEAH10

The electrical rising device FEAH1.0 allows for an automated functional test as well as electrical comfort opening of the FIRESAFE II K90.

Consists of:

  • engine and gearbox
  • base plate for mount of engine
  • adjusting tube with bearing and gearwheel
  • covering of engine
  • GSB special buckling fixture
  • device for automated release
  • control unit FSM 1

spare capillary tube sensor TLR 72/100

Firesafe II K90 Kapillarrohrfueller TLR72 100

For additional detecting in kitchen exhaust air.

Capillary tube sensor with reset button and spiral protection tube, trigger temperature 72°C.

Optionally:

Capillary tube sensor with reset button and spiral protection tube, trigger temperature 100°C (non-compliant regarding building approval Z-41.3-665)

Fire safety dowels

FIRESAFEII K90 Brandschutzduebel

Necessary for mounting the frame onto concrete walls

Description:

Thanks to a newly developed manner of straddling of the anchor bolt FAZ the weight induced into the concrete can be distributed evenly. According to authorisation, the concrete wall must possess at least 120 mm thickness and the level of concrete strength must exceed B25.

Fire protection casting and smoothing compound

Firesafe II K90 hydrosafe

After installing the shut-off device FIRESAFE II K90 the remaining gaps between walls and ceiling/ceiling and duct connection of the shut-off device must be sealed according to fire protection guidelines. The HYDROSAFE casting compound is especially well-suited for this purpose. The amount necessary for sealing the remaining gaps is determined by the size of the gap between wall or ceiling and shut-off device.

Cleaning kit

Cleaning kit for bi-annual cleaning of shut-off device FIRESAFE II

Consists of:

  • 500 ml MINT 2000 PLUS cleaning concentrate
  • spray device
  • special fleece cloth

 

back

100% unrestricted cross-section

  • less deposit
  • less cleaning expenditure
  • no additional pressure drop
  • low operating expenses
  • 100% security